Tuesday, November 3, 2009

Flash Point Tester

Sometime some error being detected done by operator or labs technician. Their hurried testing has taken all their reliable precautions.

The PMA-4 flash point tester from Petrolab Co. is suited for determining Pensky-Martens (ASTM D93) flash point automatically, eliminating operator bias. The a flame thermo-detector above the test cup. In addition, the time interval between two consecutive flash point tests is reduced to a minimum with the multi-function head. The instrument may be used with a 7- or 70-mL sample size and is available with a 12-position test cup sample changer, saving time and money.

Also available, the CLA 4 Cleveland open-cup tester is a fully automatic digital tester for ASTM D92 flash and fire point analysis of liquids, as well as highly viscous or solid samples measuring flashpoint in the range of 60 to 400 C.

The TAG-4 flash point tester is specialized for automatic low-temperature flash point determination according to ASTM D56. The user simply types in the expected flash point temperature and presses the “run” button. The instrument has an operating temperature range of -20 to 93 C (-4 to 200 F).

AMETEK Petrolab

7A Harriman Campus Road, Suite 310
Albany NY 12206
Phone: 518-689-0222
http://www.petrolab.com

Cell Disrupter and Grinder


This small-sample cell disrupter and grinder is suited for screening milligram quantities of tissue and micro-organisms, the ยต-MiniBeadbeater from BioSpec Products efficiently and safely disrupts spores, bacteria, yeast, plant and animal tissue. This compact machine uses the same high-energy homogenization process as its predecessors.

A micro vial is loaded with a large number of tiny ceramic beads, and the contents are violently shaken for 1 to 3 min to achieve +95% cell disruption. The vials and beads are disposable, making the method suitable for PAGE, PCR and probe applications where cross contamination between samples cannot be tolerated. The cell disrupter and grinder is also compatible with phenol, Gu-SCN or various commercial kit solutions. RNA/DNA is recovered quickly in the highest possible yields by doing the cell disruption and nucleic acid extraction simultaneously. Extraction in organic solvents or dry- or cryo-grinding is also possible.

BioSpec Products, Inc.
P.O. Box 788
Bartlesville OK 74005
Phone: 918-336-3363
Fax: 918-336-6060
http://www.biospec.com

CKOSCOPE10MHZ - 10MHz Single Trace Oscilloscope


This is a very affordable single trace oscilloscope, designed with the hobbyist and student in mind. Power cord and test probe included.

Specifications:

Vertical System:
Sensitivity: 5mV/DIV - 5V/DIV+- 3%
Trimming Ratio: >=2.5:1
Rise time: <=35ns Bandwidth (-3dB): DC:0-10MHz AC:10Hz - 10Mhz Input Impedance: 1 M Ohm +- 3%, 30pF, +- 5 pF Max. Input Voltage: 400V (DC + AC Peak) Trigger System: Trigger Sensitivity: INT: 1 DIV., EXT: 0.3V, TV: 2DIV Trigger Input Impedance: 1 M Ohm +- 3%, 20 pF +- 5pF Trigger Max Input: 400 Vpk Trigger Mode: Normal , Auto, TV, Lock Horizontal System: Sweep Time: 0.1S/DIV - 0.1 us/ DIV +- 3% Trimming Ratio: >=2.5:1
X-Y Mode
Sensitivity: 0.2V/DIV, -0.5V/DIV
Bandwidth (-3dB): DC: 0-1 MHz, AC: 10Hz- 1 Mhz
Calibration Signal
Waveform: Symmetric Square Wave
Range: 0.5V +- 2%
Frequency: 1 Khz +-2%

CRT:
Display Area: 8 X 10 DIV. 1 DIV=6mm
Accelerating Voltage: 1200V
Display Color: Green

Power Source:
Frequency 50Hz for 220V, 60Hz for 110V
Voltage Range: 110V/ 60Hz, 220V/50Hz
Max Power Consumption: 20W

Dimensions:
Weight: 6.6 lbs
Dimension: 11.4 x 3.5 x 8.7 inches

Wednesday, March 18, 2009

Membrane Nitrogen Generators

Parker Balston® Membrane Nitrogen Generators are designed to supply single or multiple LC/MS instruments with dry nitrogen at purities of 99% to 99.5%. The generator can also be used for solvent evaporation as well as supplying dry nitrogen to analytical instruments.

Low Flow Membrane N2 Generators
NitroFlow (includes compressor): 30 lpm nominal
N2-04: 4 slpm
N2-14, N2-14ANA: 14 slpm

Mid Flow Membrane N2 Generators
N22, N2-22ANA: 22 slpm
N2-35, N2-35ANA: 35 slpm

High Flow Membrane N2 Generators
N2-45, N2-45A: 45 lpm
N2-80, N2-80ANA: 80 lpm
N2-135, N2-135ANA: 135
NitroVap 1LV: 80 slpm
NitroVap 2LV: 160 slpm

FT-IR Purge Gas Generators

Parker Balston FT-IR Purge Gas Generators are specifically designed for use with FT-IR Spectrometers to provide a purified purge gas and air bearing gas from compressed air.

The generators supply carbon dioxide-free air at less than -100°F (-73°C) dew point with no suspended impurities larger than 0.01 micron. The units are designed to operate continuously 24 hours a day, 7 days a week. The Parker

Balston FT-IR Purge Gas Generator completely eliminates the inconvenience and the high costs of nitrogen cylinders and dewars, and significantly reduces the costs of operating all FT-IR instrumentation. Each system offers cleaner background spectra in a shorter period of time and more accurate analysis by improving the signal-to-noise ratio. The typical payback period is less than one year. The generators are also ideally suited for use with CO2 Analyzers in addition to supplying other laboratory instruments. Each generator is quiet, reliable, and easy to install - simply attach the inlet air and outlet purge lines, plug the power cord into a wall outlet, and enjoy trouble-free operation. The Model 74-5041NA Self Contained FT-IR Purge Gas Generator includes a state-of-the-art compressor.

Specifications:

Flow Rates @ Inlet Pressure of 125 psig and (60 psig):
Model 75-45NA: 36 scfh (18 scfh)
Model 75-52NA: 72 scfh (36 scfh)
Model 75-62NA: 216 scfh (120 scfh)

CO2 Concentration (all models): < 1ppm

Min/Max Inlet Air Pressure (all models): 60 psig / 125 psig

GC Gas Station

The Model GCGS-7890NA GC Gas Station can provide both hydrogen and zero grade air to FID detectors on GCs. This system is designed to provide carrier, fuel gas and support air to 1-3 FIDs and 1-3 capillary columns.

The hydrogen cell produces up to 500 cc/min of 99.99999+% pure hydrogen gas. The zero air compartment produces up to 3500 cc/min or zero grade air.

The GC Gas Station is a complete system with state-of-the-art, highly reliable components engineered for easy installation, operation, and long term performance.

Specifications:

Hydrogen Purity: 99.99999+%
Zero Air Purity: <0.05 ppm (total hydrocarbons as methane)
Maximum Hydrogen Flow Rate: 55 cc/min
Maximum Zero Air Flow Rate: 3500 cc/min
Electrical Requirements: 120 VAC, 60 Hz, 5.3 Amps
Hydrogen Outlet Pressure: 100 psig
Zero Air Outlet Pressure: 40-125 psig
Dimensions: 11"w x 27"d x 17"h (28cm x 69cm x 43cm)
Inlet Port: 1/4" NPT (female tube) compressed air supply
Outlet Ports: 1/8" Compression, Stainless
Shipping Weight: 60 lbs / 27 kg