<?xml version='1.0' encoding='UTF-8'?><?xml-stylesheet href="http://www.blogger.com/styles/atom.css" type="text/css"?><feed xmlns='http://www.w3.org/2005/Atom' xmlns:openSearch='http://a9.com/-/spec/opensearchrss/1.0/' xmlns:georss='http://www.georss.org/georss' xmlns:gd='http://schemas.google.com/g/2005' xmlns:thr='http://purl.org/syndication/thread/1.0'><id>tag:blogger.com,1999:blog-8061191680077563322</id><updated>2011-11-27T16:57:40.839-08:00</updated><category term='refractometer'/><category term='spectrophotometer'/><category term='DNA'/><category term='Grinder'/><category term='Forensic Light Source'/><category term='Tester'/><category term='Oscilloscope'/><category term='Cell Disrupter'/><category term='Flash Point'/><category term='ASTM'/><category term='centrifuge'/><category term='RNA'/><category term='Gas Generator'/><category term='Densometer'/><category term='GC/MS'/><category term='Genetic Analyzer'/><title type='text'>Labs Equipment Database</title><subtitle type='html'>Latest Information Updates On Lab Equipment, Technology,  Product and Services.</subtitle><link rel='http://schemas.google.com/g/2005#feed' type='application/atom+xml' href='http://labsequipment.blogspot.com/feeds/posts/default'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8061191680077563322/posts/default?max-results=100'/><link rel='alternate' type='text/html' href='http://labsequipment.blogspot.com/'/><link rel='hub' href='http://pubsubhubbub.appspot.com/'/><author><name>SysOp</name><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='24' src='http://3.bp.blogspot.com/_lZsIV5MoR7I/SuAKoJw84jI/AAAAAAAAAJQ/BWnYf7_4xv8/S220/cencurut2.jpg'/></author><generator version='7.00' uri='http://www.blogger.com'>Blogger</generator><openSearch:totalResults>14</openSearch:totalResults><openSearch:startIndex>1</openSearch:startIndex><openSearch:itemsPerPage>100</openSearch:itemsPerPage><entry><id>tag:blogger.com,1999:blog-8061191680077563322.post-118039771720045286</id><published>2009-11-03T00:28:00.000-08:00</published><updated>2009-11-03T00:32:04.137-08:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Flash Point'/><category scheme='http://www.blogger.com/atom/ns#' term='ASTM'/><category scheme='http://www.blogger.com/atom/ns#' term='Tester'/><title type='text'>Flash Point Tester</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://2.bp.blogspot.com/_lZsIV5MoR7I/Su_qSmt-JcI/AAAAAAAAAKA/LOBvgnGRI_I/s1600-h/astm93.jpg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 150px; height: 211px;" src="http://2.bp.blogspot.com/_lZsIV5MoR7I/Su_qSmt-JcI/AAAAAAAAAKA/LOBvgnGRI_I/s400/astm93.jpg" alt="" id="BLOGGER_PHOTO_ID_5399792083592422850" border="0" /&gt;&lt;/a&gt;Sometime some error being detected done by operator or labs technician. Their hurried testing has taken all their reliable precautions.&lt;br /&gt;&lt;br /&gt;The PMA-4 flash point tester from Petrolab Co. is suited for determining Pensky-Martens (ASTM D93) flash point automatically, eliminating operator bias. The a flame thermo-detector above the test cup. In addition, the time interval between two consecutive flash point tests is reduced to a minimum with the multi-function head. The instrument may be used with a 7- or 70-mL sample size and is available with a 12-position test cup sample changer, saving time and money.&lt;br /&gt;&lt;br /&gt;Also available, the CLA 4 Cleveland open-cup tester is a fully automatic digital tester for ASTM D92 flash and fire point analysis of liquids, as well as highly viscous or solid samples measuring flashpoint in the range of 60 to 400 C.&lt;br /&gt;&lt;br /&gt;The TAG-4 flash point tester is specialized for automatic low-temperature flash point determination according to ASTM D56. The user simply types in the expected flash point temperature and presses the “run” button. The instrument has an operating temperature range of -20 to 93 C (-4 to 200 F).&lt;!-- ##RelatedContent## --&gt;             &lt;b&gt;&lt;br /&gt;&lt;br /&gt;AMETEK Petrolab&lt;/b&gt;&lt;br /&gt;7A Harriman Campus Road, Suite 310&lt;br /&gt;Albany NY 12206&lt;br /&gt;&lt;strong&gt;Phone: &lt;/strong&gt; 518-689-0222&lt;br /&gt;&lt;a target="_blank" href="http://www.petrolab.com/"&gt;http://www.petrolab.com&lt;/a&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8061191680077563322-118039771720045286?l=labsequipment.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://labsequipment.blogspot.com/feeds/118039771720045286/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8061191680077563322&amp;postID=118039771720045286&amp;isPopup=true' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8061191680077563322/posts/default/118039771720045286'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8061191680077563322/posts/default/118039771720045286'/><link rel='alternate' type='text/html' href='http://labsequipment.blogspot.com/2009/11/flash-point-tester.html' title='Flash Point Tester'/><author><name>SysOp</name><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='24' src='http://3.bp.blogspot.com/_lZsIV5MoR7I/SuAKoJw84jI/AAAAAAAAAJQ/BWnYf7_4xv8/S220/cencurut2.jpg'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://2.bp.blogspot.com/_lZsIV5MoR7I/Su_qSmt-JcI/AAAAAAAAAKA/LOBvgnGRI_I/s72-c/astm93.jpg' height='72' width='72'/><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8061191680077563322.post-716905593898958224</id><published>2009-11-03T00:21:00.000-08:00</published><updated>2009-11-03T00:25:43.578-08:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Grinder'/><category scheme='http://www.blogger.com/atom/ns#' term='RNA'/><category scheme='http://www.blogger.com/atom/ns#' term='DNA'/><category scheme='http://www.blogger.com/atom/ns#' term='Cell Disrupter'/><title type='text'>Cell Disrupter and Grinder</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://3.bp.blogspot.com/_lZsIV5MoR7I/Su_o9p7Hm2I/AAAAAAAAAJ4/Lcw8gp_Cebg/s1600-h/le9N2_biospec_WEB.jpg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 200px; height: 163px;" src="http://3.bp.blogspot.com/_lZsIV5MoR7I/Su_o9p7Hm2I/AAAAAAAAAJ4/Lcw8gp_Cebg/s400/le9N2_biospec_WEB.jpg" alt="" id="BLOGGER_PHOTO_ID_5399790624163994466" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;This small-sample&lt;span style="font-weight: bold;"&gt; &lt;/span&gt;cell disrupter and grinder is suited for screening milligram quantities of tissue and micro-organisms, the µ-MiniBeadbeater from BioSpec Products efficiently and safely disrupts spores, bacteria, yeast, plant and animal tissue. This compact machine uses the same high-energy homogenization process as its predecessors.&lt;br /&gt;&lt;br /&gt;A micro vial is loaded with a large number of tiny ceramic beads, and the contents are violently shaken for 1 to 3 min to achieve +95% cell disruption. The vials and beads are disposable, making the method suitable for PAGE, PCR and probe applications where cross contamination between samples cannot be tolerated. The cell disrupter and grinder is also compatible with phenol, Gu-SCN or various commercial kit solutions. RNA/DNA is recovered quickly in the highest possible yields by doing the cell disruption and nucleic acid extraction simultaneously. Extraction in organic solvents or dry- or cryo-grinding is also possible.&lt;!-- ##RelatedContent## --&gt;           &lt;br /&gt;&lt;br /&gt;&lt;b&gt;BioSpec Products, Inc.&lt;/b&gt;&lt;br /&gt;P.O. Box 788&lt;br /&gt;Bartlesville OK 74005&lt;br /&gt;&lt;strong&gt;Phone: &lt;/strong&gt; 918-336-3363&lt;br /&gt;&lt;strong&gt;Fax: &lt;/strong&gt; 918-336-6060&lt;br /&gt;&lt;a target="_blank" href="http://www.biospec.com/"&gt;http://www.biospec.com&lt;/a&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8061191680077563322-716905593898958224?l=labsequipment.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://labsequipment.blogspot.com/feeds/716905593898958224/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8061191680077563322&amp;postID=716905593898958224&amp;isPopup=true' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8061191680077563322/posts/default/716905593898958224'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8061191680077563322/posts/default/716905593898958224'/><link rel='alternate' type='text/html' href='http://labsequipment.blogspot.com/2009/11/cell-disrupter-and-grinder.html' title='Cell Disrupter and Grinder'/><author><name>SysOp</name><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='24' src='http://3.bp.blogspot.com/_lZsIV5MoR7I/SuAKoJw84jI/AAAAAAAAAJQ/BWnYf7_4xv8/S220/cencurut2.jpg'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://3.bp.blogspot.com/_lZsIV5MoR7I/Su_o9p7Hm2I/AAAAAAAAAJ4/Lcw8gp_Cebg/s72-c/le9N2_biospec_WEB.jpg' height='72' width='72'/><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8061191680077563322.post-4242997750217120149</id><published>2009-11-03T00:15:00.000-08:00</published><updated>2009-11-03T00:18:55.392-08:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Oscilloscope'/><title type='text'>CKOSCOPE10MHZ - 10MHz Single Trace Oscilloscope</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://2.bp.blogspot.com/_lZsIV5MoR7I/Su_nSK7cRqI/AAAAAAAAAJw/NNCZTFx4jWc/s1600-h/CKOSCOPE10MHZpic.jpg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 320px; height: 157px;" src="http://2.bp.blogspot.com/_lZsIV5MoR7I/Su_nSK7cRqI/AAAAAAAAAJw/NNCZTFx4jWc/s320/CKOSCOPE10MHZpic.jpg" alt="" id="BLOGGER_PHOTO_ID_5399788777597847202" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;This is a very affordable single trace oscilloscope, designed with the hobbyist and student in mind.  Power cord and test probe included.&lt;br /&gt;&lt;br /&gt;Specifications:&lt;br /&gt;&lt;br /&gt;Vertical System:&lt;br /&gt;Sensitivity: 5mV/DIV - 5V/DIV+- 3%&lt;br /&gt;Trimming Ratio: &gt;=2.5:1&lt;br /&gt;Rise time: &lt;=35ns Bandwidth (-3dB): DC:0-10MHz AC:10Hz - 10Mhz Input Impedance: 1 M Ohm +- 3%, 30pF, +- 5 pF Max. Input Voltage: 400V (DC + AC Peak)  Trigger System: Trigger Sensitivity: INT: 1 DIV., EXT: 0.3V, TV: 2DIV Trigger Input Impedance: 1 M Ohm +- 3%, 20 pF +- 5pF Trigger Max Input: 400 Vpk Trigger Mode: Normal , Auto, TV, Lock  Horizontal System: Sweep Time: 0.1S/DIV - 0.1 us/ DIV +- 3% Trimming Ratio: &gt;=2.5:1&lt;br /&gt;X-Y Mode&lt;br /&gt;Sensitivity: 0.2V/DIV, -0.5V/DIV&lt;br /&gt;Bandwidth (-3dB): DC: 0-1 MHz, AC: 10Hz- 1 Mhz&lt;br /&gt;Calibration Signal&lt;br /&gt;Waveform: Symmetric Square Wave&lt;br /&gt;Range: 0.5V +- 2%&lt;br /&gt;Frequency: 1 Khz +-2%&lt;br /&gt;&lt;br /&gt;CRT:&lt;br /&gt;Display Area: 8 X 10 DIV. 1 DIV=6mm&lt;br /&gt;Accelerating Voltage: 1200V&lt;br /&gt;Display Color: Green&lt;br /&gt;&lt;br /&gt;Power Source:&lt;br /&gt;Frequency 50Hz for 220V, 60Hz for 110V&lt;br /&gt;Voltage Range: 110V/ 60Hz, 220V/50Hz&lt;br /&gt;Max Power Consumption: 20W&lt;br /&gt;&lt;br /&gt;Dimensions:&lt;br /&gt;Weight: 6.6 lbs&lt;br /&gt;Dimension: 11.4 x 3.5 x 8.7 inches&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8061191680077563322-4242997750217120149?l=labsequipment.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://labsequipment.blogspot.com/feeds/4242997750217120149/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8061191680077563322&amp;postID=4242997750217120149&amp;isPopup=true' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8061191680077563322/posts/default/4242997750217120149'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8061191680077563322/posts/default/4242997750217120149'/><link rel='alternate' type='text/html' href='http://labsequipment.blogspot.com/2009/11/ckoscope10mhz-10mhz-single-trace.html' title='CKOSCOPE10MHZ - 10MHz Single Trace Oscilloscope'/><author><name>SysOp</name><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='24' src='http://3.bp.blogspot.com/_lZsIV5MoR7I/SuAKoJw84jI/AAAAAAAAAJQ/BWnYf7_4xv8/S220/cencurut2.jpg'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://2.bp.blogspot.com/_lZsIV5MoR7I/Su_nSK7cRqI/AAAAAAAAAJw/NNCZTFx4jWc/s72-c/CKOSCOPE10MHZpic.jpg' height='72' width='72'/><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8061191680077563322.post-4543618416038173145</id><published>2009-03-18T05:03:00.001-07:00</published><updated>2009-03-18T05:03:54.397-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='GC/MS'/><category scheme='http://www.blogger.com/atom/ns#' term='Gas Generator'/><title type='text'>Membrane Nitrogen Generators</title><content type='html'>Parker Balston® Membrane Nitrogen Generators are designed to supply single or multiple LC/MS instruments with dry nitrogen at purities of 99% to 99.5%. The generator can also be used for solvent evaporation as well as supplying dry nitrogen to analytical instruments.&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;Low Flow Membrane N2 Generators&lt;/strong&gt;&lt;br /&gt;NitroFlow (includes compressor):  30 lpm nominal&lt;br /&gt;N2-04: 4 slpm&lt;br /&gt;N2-14, N2-14ANA:  14 slpm&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;Mid Flow Membrane N2 Generators&lt;/strong&gt;&lt;br /&gt;N22, N2-22ANA:  22 slpm&lt;br /&gt;N2-35, N2-35ANA:  35 slpm&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;High Flow Membrane N2 Generators&lt;/strong&gt;&lt;br /&gt;N2-45, N2-45A:  45 lpm&lt;br /&gt;N2-80, N2-80ANA:  80 lpm&lt;br /&gt;N2-135, N2-135ANA:  135&lt;br /&gt;NitroVap 1LV:  80 slpm&lt;br /&gt;NitroVap 2LV:  160 slpm&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8061191680077563322-4543618416038173145?l=labsequipment.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://labsequipment.blogspot.com/feeds/4543618416038173145/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8061191680077563322&amp;postID=4543618416038173145&amp;isPopup=true' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8061191680077563322/posts/default/4543618416038173145'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8061191680077563322/posts/default/4543618416038173145'/><link rel='alternate' type='text/html' href='http://labsequipment.blogspot.com/2009/03/membrane-nitrogen-generators.html' title='Membrane Nitrogen Generators'/><author><name>SysOp</name><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='24' src='http://3.bp.blogspot.com/_lZsIV5MoR7I/SuAKoJw84jI/AAAAAAAAAJQ/BWnYf7_4xv8/S220/cencurut2.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8061191680077563322.post-6858820260858909337</id><published>2009-03-18T05:01:00.000-07:00</published><updated>2009-03-18T05:02:30.600-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Gas Generator'/><title type='text'>FT-IR Purge Gas Generators</title><content type='html'>Parker Balston FT-IR Purge Gas Generators are specifically designed for use with FT-IR Spectrometers to provide a purified purge gas and air bearing gas from compressed air. &lt;br /&gt;&lt;br /&gt;The generators supply carbon dioxide-free air at less than -100°F (-73°C) dew point with no suspended impurities larger than 0.01 micron.  The units are designed to operate continuously 24 hours a day, 7 days a week.  The Parker&lt;br /&gt;&lt;br /&gt;Balston FT-IR Purge Gas Generator completely eliminates the inconvenience and the high costs of nitrogen cylinders and dewars, and significantly reduces the costs of operating all FT-IR instrumentation.  Each system offers cleaner background spectra in a shorter period of time and more accurate analysis by improving the signal-to-noise ratio.  The typical payback period is less than one year.  The generators are also ideally suited for use with CO2 Analyzers in addition to supplying other laboratory instruments.  Each generator is quiet, reliable, and easy to install - simply attach the inlet air and outlet purge lines, plug the power cord into a wall outlet, and enjoy trouble-free operation.  The Model 74-5041NA Self Contained FT-IR Purge Gas Generator includes a state-of-the-art compressor.&lt;br /&gt;&lt;br /&gt;Specifications:&lt;br /&gt;&lt;br /&gt;Flow Rates @ Inlet Pressure of 125 psig and (60 psig): &lt;br /&gt;Model 75-45NA:  36 scfh (18 scfh)&lt;br /&gt;Model 75-52NA:  72 scfh (36 scfh)&lt;br /&gt;Model 75-62NA:  216 scfh (120 scfh)&lt;br /&gt;&lt;br /&gt;CO2 Concentration (all models):  &lt; 1ppm&lt;br /&gt;&lt;br /&gt;Min/Max Inlet Air Pressure (all models):  60 psig / 125 psig&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8061191680077563322-6858820260858909337?l=labsequipment.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://labsequipment.blogspot.com/feeds/6858820260858909337/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8061191680077563322&amp;postID=6858820260858909337&amp;isPopup=true' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8061191680077563322/posts/default/6858820260858909337'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8061191680077563322/posts/default/6858820260858909337'/><link rel='alternate' type='text/html' href='http://labsequipment.blogspot.com/2009/03/ft-ir-purge-gas-generators.html' title='FT-IR Purge Gas Generators'/><author><name>SysOp</name><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='24' src='http://3.bp.blogspot.com/_lZsIV5MoR7I/SuAKoJw84jI/AAAAAAAAAJQ/BWnYf7_4xv8/S220/cencurut2.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8061191680077563322.post-6570077898079039179</id><published>2009-03-18T04:52:00.000-07:00</published><updated>2009-03-18T05:00:53.127-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='GC/MS'/><title type='text'>GC Gas Station</title><content type='html'>The Model GCGS-7890NA GC Gas Station can provide both hydrogen and zero grade air to FID detectors on GCs.  This system is designed to provide carrier, fuel gas and support air to 1-3 FIDs and 1-3 capillary columns.&lt;br /&gt;&lt;br /&gt;The hydrogen cell produces up to 500 cc/min of 99.99999+% pure hydrogen gas.  The zero air compartment produces up to 3500 cc/min or zero grade air.&lt;br /&gt;&lt;br /&gt;The GC Gas Station is a complete system with state-of-the-art, highly reliable components engineered for easy installation, operation, and long term performance.&lt;br /&gt;&lt;br /&gt;Specifications:&lt;br /&gt;&lt;br /&gt;Hydrogen Purity:  99.99999+%&lt;br /&gt;Zero Air Purity:  &lt;0.05 ppm (total hydrocarbons as methane)&lt;br /&gt;Maximum Hydrogen Flow Rate:  55 cc/min&lt;br /&gt;Maximum Zero Air Flow Rate:  3500 cc/min&lt;br /&gt;Electrical Requirements:  120 VAC, 60 Hz, 5.3 Amps&lt;br /&gt;Hydrogen Outlet Pressure:  100 psig&lt;br /&gt;Zero Air Outlet Pressure:  40-125 psig&lt;br /&gt;Dimensions:  11"w x 27"d x 17"h (28cm x 69cm x 43cm)&lt;br /&gt;Inlet Port:  1/4" NPT (female tube) compressed air supply&lt;br /&gt;Outlet Ports:  1/8" Compression, Stainless&lt;br /&gt;Shipping Weight:  60 lbs / 27 kg&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8061191680077563322-6570077898079039179?l=labsequipment.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://labsequipment.blogspot.com/feeds/6570077898079039179/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8061191680077563322&amp;postID=6570077898079039179&amp;isPopup=true' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8061191680077563322/posts/default/6570077898079039179'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8061191680077563322/posts/default/6570077898079039179'/><link rel='alternate' type='text/html' href='http://labsequipment.blogspot.com/2009/03/gc-gas-station.html' title='GC Gas Station'/><author><name>SysOp</name><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='24' src='http://3.bp.blogspot.com/_lZsIV5MoR7I/SuAKoJw84jI/AAAAAAAAAJQ/BWnYf7_4xv8/S220/cencurut2.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8061191680077563322.post-4063804383100413583</id><published>2007-10-21T01:42:00.000-07:00</published><updated>2007-10-21T01:48:10.285-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Genetic Analyzer'/><title type='text'>DELFIA 1234 fluorometer</title><content type='html'>The Wallac DELFIA 1234 fluorometer detects fluorescence from europium, samarium and terbium lanthanide chelates. It measures samples directly from the plate and allows measurement over a very wide dynamic range down to extremely low concentrations. Measurement time is only 1 second per sample or about 3 minutes for a whole plate.&lt;br /&gt;&lt;br /&gt;There is a built-in 40-character alphanumeric display, or the instrument may be controlled by a PC running MultiCalc software. A bar-code reader allows automatic call-up of protocol and worklists.&lt;br /&gt;&lt;ul&gt;&lt;li&gt;High sensitivity&lt;/li&gt;&lt;li&gt;Multi-label assays possible&lt;/li&gt;&lt;li&gt;Unbeatable sensitivity, dynamic range, and consistency of results&lt;/li&gt;&lt;li&gt;More than 1000 scientific references&lt;/li&gt;&lt;li&gt;Monitor induction of up to three surface antigens in one well&lt;/li&gt;&lt;li&gt;Ready made protocols with commercially available receptors&lt;/li&gt;&lt;/ul&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8061191680077563322-4063804383100413583?l=labsequipment.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://labsequipment.blogspot.com/feeds/4063804383100413583/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8061191680077563322&amp;postID=4063804383100413583&amp;isPopup=true' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8061191680077563322/posts/default/4063804383100413583'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8061191680077563322/posts/default/4063804383100413583'/><link rel='alternate' type='text/html' href='http://labsequipment.blogspot.com/2007/10/delfia-1234-fluorometer.html' title='DELFIA 1234 fluorometer'/><author><name>SysOp</name><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='24' src='http://3.bp.blogspot.com/_lZsIV5MoR7I/SuAKoJw84jI/AAAAAAAAAJQ/BWnYf7_4xv8/S220/cencurut2.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8061191680077563322.post-8655258872388399292</id><published>2007-10-20T20:58:00.000-07:00</published><updated>2007-10-20T21:04:16.902-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Forensic Light Source'/><title type='text'>Polilight PL500</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://2.bp.blogspot.com/_lZsIV5MoR7I/RxrPCCYxW5I/AAAAAAAAACo/pttIVkWzzUk/s1600-h/pl500.jpg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer;" src="http://2.bp.blogspot.com/_lZsIV5MoR7I/RxrPCCYxW5I/AAAAAAAAACo/pttIVkWzzUk/s320/pl500.jpg" alt="" id="BLOGGER_PHOTO_ID_5123635159994817426" border="0" /&gt;&lt;/a&gt;The Polilight 500 is a high-intensity light source based on a 500-watt xenon arc lamp. This type of lamp delivers UV, visible, and infrared light. A special characteristic of the light output in the visible region is that the intensity of light is the same in the whole spectrum, just like sun light. This is in contrast with halogen lamps that deliver progressively more light, going from blue (low wavelength) to red (high wavelength). &lt;p class="bijschrift"&gt;Apart from white light, the Polilight 500 has 11 selectable  wavebands (from UV to red light). With filter tuning, any narrow band of light  (with width of about 40 nm) in the visible spectrum can be selected.&lt;/p&gt; &lt;p class="bijschrift"&gt;The waveband is selected either by using the buttons on  the front panel, or stepwise with the remote control (2 m-long cable). The  filter selection and fine tuning are operated internally by stepper motors. The  remote control is attached to the unit through a RS232 port.&lt;/p&gt; &lt;p class="bijschrift"&gt;This port can also be used for operating the PL500 from a computer (using optionally available software). Also available is a security code option that uses the filter selection buttons. This option will prevent unauthorized persons from switching on the instrument.&lt;br /&gt;&lt;br /&gt;With the remote control or the buttons on the front panel, the light power can also be tuned (8 settings, from about 15 to 100% in equal increments).&lt;/p&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8061191680077563322-8655258872388399292?l=labsequipment.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://labsequipment.blogspot.com/feeds/8655258872388399292/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8061191680077563322&amp;postID=8655258872388399292&amp;isPopup=true' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8061191680077563322/posts/default/8655258872388399292'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8061191680077563322/posts/default/8655258872388399292'/><link rel='alternate' type='text/html' href='http://labsequipment.blogspot.com/2007/10/polilight-500.html' title='Polilight PL500'/><author><name>SysOp</name><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='24' src='http://3.bp.blogspot.com/_lZsIV5MoR7I/SuAKoJw84jI/AAAAAAAAAJQ/BWnYf7_4xv8/S220/cencurut2.jpg'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://2.bp.blogspot.com/_lZsIV5MoR7I/RxrPCCYxW5I/AAAAAAAAACo/pttIVkWzzUk/s72-c/pl500.jpg' height='72' width='72'/><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8061191680077563322.post-7925742778218690614</id><published>2007-10-09T17:25:00.000-07:00</published><updated>2007-10-09T17:31:41.236-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='centrifuge'/><title type='text'>Microfuge 18 Microcentrifuge</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://3.bp.blogspot.com/_lZsIV5MoR7I/RwwdTyYxW4I/AAAAAAAAACg/C_e7n4WEnak/s1600-h/mfu18glory.jpg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer;" src="http://3.bp.blogspot.com/_lZsIV5MoR7I/RwwdTyYxW4I/AAAAAAAAACg/C_e7n4WEnak/s320/mfu18glory.jpg" alt="" id="BLOGGER_PHOTO_ID_5119499102193802114" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;strong&gt;Fast - Powerful &lt;em&gt;g&lt;/em&gt;-Force for Fast and Optimal Pelleti&lt;/strong&gt;&lt;strong&gt;ng&lt;/strong&gt;  &lt;ul&gt;&lt;li&gt;Maintenance-free rotor spins up to 14,000 rpm (18,000 x &lt;em&gt;g&lt;/em&gt;)&lt;/li&gt;&lt;li&gt;Ideal for fast pelleting of DNA, RNA and proteins, and cell virus isolation&lt;/li&gt;&lt;li&gt;Fits on crowded bench or in a cold room&lt;/li&gt;&lt;li&gt;Comes complete with a 24-place aerosol-tight, autoclavable fixed-angle rotor&lt;/li&gt;&lt;li&gt;Quiet operation — &lt;u&gt;&lt;&lt;/u&gt; 58 dBa&lt;/li&gt;&lt;li&gt; Easy-to-read interface displays both speed (rpm) and force (rcf)      &lt;/li&gt;&lt;li&gt; Runtime options - timed, hold or pulse      &lt;/li&gt;&lt;li&gt; Easy-to-use knobs      &lt;/li&gt;&lt;/ul&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8061191680077563322-7925742778218690614?l=labsequipment.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://labsequipment.blogspot.com/feeds/7925742778218690614/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8061191680077563322&amp;postID=7925742778218690614&amp;isPopup=true' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8061191680077563322/posts/default/7925742778218690614'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8061191680077563322/posts/default/7925742778218690614'/><link rel='alternate' type='text/html' href='http://labsequipment.blogspot.com/2007/10/microfuge-18-microcentrifuge.html' title='Microfuge 18 Microcentrifuge'/><author><name>SysOp</name><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='24' src='http://3.bp.blogspot.com/_lZsIV5MoR7I/SuAKoJw84jI/AAAAAAAAAJQ/BWnYf7_4xv8/S220/cencurut2.jpg'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://3.bp.blogspot.com/_lZsIV5MoR7I/RwwdTyYxW4I/AAAAAAAAACg/C_e7n4WEnak/s72-c/mfu18glory.jpg' height='72' width='72'/><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8061191680077563322.post-4702722418243542772</id><published>2007-10-06T23:06:00.000-07:00</published><updated>2007-10-06T23:16:21.599-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Densometer'/><title type='text'>Nuclear Densometer</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://4.bp.blogspot.com/_lZsIV5MoR7I/Rwh5oCYxW1I/AAAAAAAAACI/8PAE1cJV400/s1600-h/nuclear_densometer_acc.jpg"&gt;&lt;img style="cursor: pointer;" src="http://4.bp.blogspot.com/_lZsIV5MoR7I/Rwh5oCYxW1I/AAAAAAAAACI/8PAE1cJV400/s320/nuclear_densometer_acc.jpg" alt="" id="BLOGGER_PHOTO_ID_5118474705249065810" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;Troxler 3440 Advanced Nuclear Moisture/Density Gauge&lt;br /&gt;&lt;br /&gt;The general purpose Moisture/Density gauges  like the 3440 and 3430 are calibrated for soil,  not asphalt, which featured:&lt;br /&gt;&lt;ul&gt;&lt;li&gt;The 3440 can store data to download later into a computer.&lt;/li&gt;&lt;li&gt;The 3440 has a more sophisticated display.&lt;/li&gt;&lt;li&gt;The 3440 model has depth indicator.&lt;/li&gt;&lt;/ul&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8061191680077563322-4702722418243542772?l=labsequipment.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://labsequipment.blogspot.com/feeds/4702722418243542772/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8061191680077563322&amp;postID=4702722418243542772&amp;isPopup=true' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8061191680077563322/posts/default/4702722418243542772'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8061191680077563322/posts/default/4702722418243542772'/><link rel='alternate' type='text/html' href='http://labsequipment.blogspot.com/2007/10/nuclear-densometer.html' title='Nuclear Densometer'/><author><name>SysOp</name><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='24' src='http://3.bp.blogspot.com/_lZsIV5MoR7I/SuAKoJw84jI/AAAAAAAAAJQ/BWnYf7_4xv8/S220/cencurut2.jpg'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://4.bp.blogspot.com/_lZsIV5MoR7I/Rwh5oCYxW1I/AAAAAAAAACI/8PAE1cJV400/s72-c/nuclear_densometer_acc.jpg' height='72' width='72'/><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8061191680077563322.post-4561588502561788569</id><published>2007-10-04T19:59:00.000-07:00</published><updated>2007-10-04T20:08:19.149-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='refractometer'/><title type='text'>Reichert* Abbe* Mark III Refractometer</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://4.bp.blogspot.com/_lZsIV5MoR7I/RwWqhyYxWyI/AAAAAAAAABw/uX6IlQKjAb8/s1600-h/refractometer.jpg"&gt;&lt;img style="cursor: pointer;" src="http://4.bp.blogspot.com/_lZsIV5MoR7I/RwWqhyYxWyI/AAAAAAAAABw/uX6IlQKjAb8/s320/refractometer.jpg" alt="" id="BLOGGER_PHOTO_ID_5117684049014512418" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;table class="articleTitle" id="WC_CachedProductDisplay_Table_2" border="0" cellpadding="0" cellspacing="0" width="95%"&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td&gt;&lt;table class="articleTitle" id="WC_CachedProductDisplay_Table_2" border="0" cellpadding="0" cellspacing="0" width="95%"&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td&gt;&lt;br /&gt;&lt;/td&gt;&lt;td id="WC_CachedProductDisplay_TableCell_3" valign="top"&gt;     &lt;br /&gt;&lt;/td&gt;&lt;td colspan="2" valign="top"&gt;   &lt;!-- added this today 06/19/2007 --&gt;              &lt;!--  PRODUCT HEADER ENDING  MOVED PRODHEADER INTO INNER BOX...BEGINNING --&gt;           &lt;span style="font-weight: bold;"&gt;&lt;br /&gt;&lt;br /&gt;&lt;/span&gt; &lt;!--  PRODUCT HEADER ENDING  MOVED PRODHEADER INTO INNER BOX...ENDING--&gt;                       &lt;table border="0" cellpadding="0" cellspacing="2"&gt;                 &lt;tbody&gt;&lt;tr&gt;                                                                              &lt;td valign="top"&gt; Manual refractometer with computerized interpretation and data handling A modern version of the classic Abbe refractometer, with operating features of the Reichert Abbe Mark II Plus and advanced features found on the Reichert Arias 500. &lt;p style="margin-top: 0.5em; margin-bottom: 0.5em;"&gt;&lt;b&gt;Simple operation&lt;/b&gt;&lt;/p&gt;&lt;ul style="margin-top: 0px; margin-bottom: 0px; list-style-type: square;"&gt;&lt;li&gt;Five-button operation, with MENU, SELECT, READ and arrow keys&lt;/li&gt;&lt;li&gt;Multilingual instructions in English, German, Spanish, French&lt;/li&gt;&lt;li&gt;To operate, just place the shadowline intersect in the center of the crosshair and press the READ button&lt;/li&gt;&lt;li&gt;Graphic LCD, 17/8W x 17/8 in.H (4.7 x 4.7cm), gives direct measurement readout&lt;/li&gt;&lt;li&gt;Accuracy is enhanced by Automatic Temperature Equilibration Detection software and Automatic Temperature Compensation&lt;/li&gt;&lt;li&gt;Set Point or Set Point/Span (user definable) calibration&lt;/li&gt;&lt;/ul&gt;&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;/td&gt;          &lt;td id="WC_CachedProductDisplay_TableCell_3" valign="top"&gt;&lt;br /&gt;&lt;/td&gt;&lt;td colspan="2" valign="top"&gt;&lt;br /&gt;&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8061191680077563322-4561588502561788569?l=labsequipment.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://labsequipment.blogspot.com/feeds/4561588502561788569/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8061191680077563322&amp;postID=4561588502561788569&amp;isPopup=true' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8061191680077563322/posts/default/4561588502561788569'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8061191680077563322/posts/default/4561588502561788569'/><link rel='alternate' type='text/html' href='http://labsequipment.blogspot.com/2007/10/reichert-abbe-mark-iii-refractometer.html' title='Reichert* Abbe* Mark III Refractometer'/><author><name>SysOp</name><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='24' src='http://3.bp.blogspot.com/_lZsIV5MoR7I/SuAKoJw84jI/AAAAAAAAAJQ/BWnYf7_4xv8/S220/cencurut2.jpg'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://4.bp.blogspot.com/_lZsIV5MoR7I/RwWqhyYxWyI/AAAAAAAAABw/uX6IlQKjAb8/s72-c/refractometer.jpg' height='72' width='72'/><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8061191680077563322.post-787999206563859594</id><published>2007-10-02T17:15:00.000-07:00</published><updated>2007-10-02T17:20:04.525-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='centrifuge'/><title type='text'>Lab Centrifuge</title><content type='html'>&lt;span style=";font-family:VERDANA;font-size:85%;"  &gt;&lt;span style=";font-family:arial;font-size:130%;"  &gt;&lt;span style="font-size:85%;"&gt;&lt;span style="font-weight: bold;"&gt;Application :&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;The laboratory centrifuge has been designed by Rousselet Robatel for use in Laboratories specialising in fine chemicals, pharmaceuticals, biotechnology, research and food processing.&lt;br /&gt;&lt;br /&gt;Its versatility allows a utilisation for laboratory as well as pilot plant trials and even for small scale production. Constructed according to industrial manufacturing standards enables it to perform under the most arduous conditions with highly corrosive and flammable materials.&lt;br /&gt;&lt;br /&gt;Robust, relaible and easily maintained, this machine is characterised by its adaptability. By interchanging some elements it allows you to investigate and solve a wide range of solid/liquid separation problems.&lt;br /&gt;&lt;br /&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://1.bp.blogspot.com/_lZsIV5MoR7I/RwLfZyYxWoI/AAAAAAAAAAg/iIhJfz5O6V0/s1600-h/centrifuge.jpg"&gt;&lt;img style="cursor: pointer;" src="http://1.bp.blogspot.com/_lZsIV5MoR7I/RwLfZyYxWoI/AAAAAAAAAAg/iIhJfz5O6V0/s320/centrifuge.jpg" alt="" id="BLOGGER_PHOTO_ID_5116897760761698946" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;span style=";font-family:VERDANA;font-size:85%;"  &gt;&lt;span style=";font-family:arial;font-size:130%;"  &gt;&lt;span style="font-size:85%;"&gt; &lt;b&gt;&lt;br /&gt;General features :&lt;/b&gt;&lt;br /&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;ul&gt;&lt;li&gt;&lt;span style=";font-family:VERDANA;font-size:85%;"  &gt;&lt;span style=";font-family:arial;font-size:130%;"  &gt;&lt;span style="font-size:85%;"&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/li&gt;&lt;span style=";font-family:VERDANA;font-size:85%;"  &gt;&lt;span style=";font-family:arial;font-size:130%;"  &gt;&lt;span style="font-size:85%;"&gt;&lt;li&gt;Rigid construction. Vertical axis centrifuge mounted on 4 anti-vibration rubber dampers. &lt;/li&gt;&lt;li&gt;Basket : diameter 200 mm (RC20) 300 mm (RC 30) with removable filtration bag. Rotation speed 3000 rpm. &lt;/li&gt;&lt;li&gt;Lid with sealing gasket and safety locking, fitted with feeding pipe and sight glass. &lt;/li&gt;&lt;li&gt;Drive : the basket is driven in rotation by a single speed electric motor via a V-Belt connected to a frequency invertor to achieve starting, braking and variable speed. All the electrical equipment mounted on the machine is built according to IP 55 standards. &lt;/li&gt;&lt;li&gt;Safety : centrifuge equipped with all safety devices. &lt;/li&gt;&lt;li&gt;Control of the centrifuge from a control box mounted on the centrifuge. Control panel containing contactors located in safe area. &lt;/li&gt;&lt;li&gt;Material : all product wetted parts are manufactured from stainless steel AISI 316 (L &amp;amp; ti)&lt;/li&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/ul&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8061191680077563322-787999206563859594?l=labsequipment.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://labsequipment.blogspot.com/feeds/787999206563859594/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8061191680077563322&amp;postID=787999206563859594&amp;isPopup=true' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8061191680077563322/posts/default/787999206563859594'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8061191680077563322/posts/default/787999206563859594'/><link rel='alternate' type='text/html' href='http://labsequipment.blogspot.com/2007/10/lab-centrifuge.html' title='Lab Centrifuge'/><author><name>SysOp</name><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='24' src='http://3.bp.blogspot.com/_lZsIV5MoR7I/SuAKoJw84jI/AAAAAAAAAJQ/BWnYf7_4xv8/S220/cencurut2.jpg'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://1.bp.blogspot.com/_lZsIV5MoR7I/RwLfZyYxWoI/AAAAAAAAAAg/iIhJfz5O6V0/s72-c/centrifuge.jpg' height='72' width='72'/><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8061191680077563322.post-7017280080525914762</id><published>2007-10-02T17:04:00.000-07:00</published><updated>2007-10-02T17:19:09.392-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='spectrophotometer'/><title type='text'>Spectrophotometer</title><content type='html'>&lt;span style="font-weight: bold;"&gt;LCS-II Spectrophotometer&lt;/span&gt;&lt;div class="productsDescriptions"&gt; &lt;!-- /productsDescriptions --&gt;&lt;/div&gt;&lt;!-- === products-descriptions === --&gt; &lt;!-- === description-block01 === --&gt;      &lt;p&gt;&lt;span style=";font-family:Verdana;font-size:85%;"  &gt;The LCS-II (manufactured by Konica Minolta Inc) precisely measures the color of &lt;span style="font-family:Arial;"&gt;all&lt;/span&gt; optically clear liquids and is ideal for beverages, food, petroleum, pharmaceuticals, cosmetics, chemicals.    In addition to standard color scales, the LCS-II includes Gardner, APHA or Hazen, ASTM D1500, Lovibond, and Pharmacopoeia.  That means you can use it ithe LCS-II in applications as varied as checking water contaminants at industrial sites, or measuring the color of injectable drugs and medications.&lt;/span&gt;&lt;span style=";font-family:Verdana;font-size:85%;"  &gt;&lt;br /&gt;&lt;/span&gt;&lt;/p&gt;&lt;p&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://2.bp.blogspot.com/_lZsIV5MoR7I/RwLdgCYxWnI/AAAAAAAAAAY/XRkYMBq07wc/s1600-h/Spectrophotometer.jpg"&gt;&lt;img style="cursor: pointer;" src="http://2.bp.blogspot.com/_lZsIV5MoR7I/RwLdgCYxWnI/AAAAAAAAAAY/XRkYMBq07wc/s320/Spectrophotometer.jpg" alt="" id="BLOGGER_PHOTO_ID_5116895669112625778" border="0" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;p&gt;&lt;span style=";font-family:Verdana;font-size:85%;"  &gt;The LCS-II comes equipped with software to give statistical evaluations as well as spectral graphs, and the instrument can be operated as a stand-alone - no PC is required.&lt;/span&gt;&lt;/p&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8061191680077563322-7017280080525914762?l=labsequipment.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://labsequipment.blogspot.com/feeds/7017280080525914762/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8061191680077563322&amp;postID=7017280080525914762&amp;isPopup=true' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8061191680077563322/posts/default/7017280080525914762'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8061191680077563322/posts/default/7017280080525914762'/><link rel='alternate' type='text/html' href='http://labsequipment.blogspot.com/2007/10/spectrophotometer.html' title='Spectrophotometer'/><author><name>SysOp</name><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='24' src='http://3.bp.blogspot.com/_lZsIV5MoR7I/SuAKoJw84jI/AAAAAAAAAJQ/BWnYf7_4xv8/S220/cencurut2.jpg'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://2.bp.blogspot.com/_lZsIV5MoR7I/RwLdgCYxWnI/AAAAAAAAAAY/XRkYMBq07wc/s72-c/Spectrophotometer.jpg' height='72' width='72'/><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8061191680077563322.post-1527319249874158430</id><published>2007-10-02T01:57:00.000-07:00</published><updated>2007-10-02T17:19:32.873-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='GC/MS'/><title type='text'>Gas Chromatography (GC/MS)</title><content type='html'>Listed here is one of the best Gas Chromatography (GC/MS) equipment available from Varian. Varian manufacture many type or model of GC/MS including one in this picture.&lt;br /&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://3.bp.blogspot.com/_lZsIV5MoR7I/RwIN_SYxWmI/AAAAAAAAAAM/n9xZy4dHhb8/s1600-h/gcms4000.jpg"&gt;&lt;img style="cursor: pointer;" src="http://3.bp.blogspot.com/_lZsIV5MoR7I/RwIN_SYxWmI/AAAAAAAAAAM/n9xZy4dHhb8/s320/gcms4000.jpg" alt="" id="BLOGGER_PHOTO_ID_5116667507564960354" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;p&gt;The Varian 4000 GC/MS system offers three easily switchable ionization configurations:                       internal ionization (II),  external ionization (EI) or hybrid chemical ionization        (CI). &lt;/p&gt;            &lt;div align="center"&gt;    &lt;table&gt;    &lt;tbody&gt;&lt;tr&gt;&lt;td class="subhead006699"&gt;· &lt;a href="http://www.varianinc.com/nav/products/chrom/gcms/gcms4000ei&amp;amp;cid=HFIH"&gt;External Ionization&lt;/a&gt;&lt;/td&gt;    &lt;/tr&gt;             &lt;tr&gt;                   &lt;td class="subhead006699"&gt;· &lt;a href="http://www.varianinc.com/nav/products/chrom/gcms/gcms4000ii&amp;amp;cid=HFIH"&gt;Internal Ionization&lt;/a&gt;&lt;/td&gt;             &lt;/tr&gt;             &lt;tr&gt;&lt;td class="subhead006699"&gt;· &lt;a href="http://www.varianinc.com/nav/products/chrom/gcms/gcms4000hybrid&amp;amp;cid=HFIH"&gt;Hybrid Chemical Ionization (CI)&lt;/a&gt;&lt;/td&gt;             &lt;/tr&gt;              &lt;/tbody&gt;&lt;/table&gt;    &lt;/div&gt;                                                                       &lt;p&gt;Sample introduction and separation is handled by the Varian CP-3800 GC with                       its proven performance and many options. Varian MS Workstation controls the                       4000 GC/MS with a full complement of productivity, reporting, and regulatory                       compliance tools.&lt;/p&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8061191680077563322-1527319249874158430?l=labsequipment.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://labsequipment.blogspot.com/feeds/1527319249874158430/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8061191680077563322&amp;postID=1527319249874158430&amp;isPopup=true' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8061191680077563322/posts/default/1527319249874158430'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8061191680077563322/posts/default/1527319249874158430'/><link rel='alternate' type='text/html' href='http://labsequipment.blogspot.com/2007/10/gas-chromatography.html' title='Gas Chromatography (GC/MS)'/><author><name>SysOp</name><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='24' src='http://3.bp.blogspot.com/_lZsIV5MoR7I/SuAKoJw84jI/AAAAAAAAAJQ/BWnYf7_4xv8/S220/cencurut2.jpg'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://3.bp.blogspot.com/_lZsIV5MoR7I/RwIN_SYxWmI/AAAAAAAAAAM/n9xZy4dHhb8/s72-c/gcms4000.jpg' height='72' width='72'/><thr:total>0</thr:total></entry></feed>
